33
Preset parameters
To machine off, press the button
and turn the machine.
When the display shows the
PrS
, release the button and shut down and restart the machine.
Reset all values to the table above, for the desired temperature refer to the diagram ”temperature
range”
Default settings TermoPid
EUROPA
AMERICA
Parametri
Display
Parametri
Display
F.01
°C
F.01
°F
F.02
5-7
F.02
7
P
1.
3
P
1.3
I
00
6
I
006
D
1.5
D
1.5
T1
93
T1
200
T2
123 (min 121- max 128)
T2
255 (min 248- max 262)
T3
80
T3
176
E1
10
E1
18
E2
0
E2
0
E3
0
E3
0
Temperatura range
CELSIUS
FAHRENHEIT
BAR
INFORMATION
120
248
1
turn the machine on and wait about 14-15 minutes to
bring the temperature from 0 to 120 degrees
121
249.8
1.1
122
251.6
1.15
T1 = coffee boiler
123
253.4
1.2
T2 = boiler water and steam
124
255.2
1.3
125
257
1.35
126
258.8
1.4
127
260.6
1.45
128
262.4
1.5
Ceiling
Alarms
In case of malfunction, the display shows the following warning messages:
Channel 1 disconnected (
A1
), channel 1 short-circuit (
A2
), Channel 2 disconnected (
A3
), channel
2 short-circuit (
A4
).
Summary of Contents for Alex Pid III
Page 1: ......
Page 4: ...7...
Page 5: ...8 Descrizione description...
Page 7: ...10 Schema Impianto Elettrico Alex Pid...
Page 8: ...11 Schema Impianto Elettrico Vivi Pid...
Page 10: ...13 Schema Impianto Elettrico Alex Duetto...
Page 13: ...16 1 ITALIANO...
Page 24: ...27 2 ENGLISH...
Page 37: ...40 3 DEUTSCH...
Page 52: ......