31
2.5 FUNCTIONS OF THE DISPLAY (for VIVI PID and ALEX PID model)
In addition to numeric values, the display
shows a blinking LED that indicates that
the resistance is operating.
To turn off the heating elements
press the button
for about 2
seconds and the display
oFF.
To activate the resistance of the coffee
boiler, just press the
button For set
point programming the press the button
when the display shows
PrG
press the
button
.
Select by pressing
and
, the desired temperature, a minimum of
121°C
for a maximum
of
128°C
. After 3 seconds the display shows the selected temperature.
Adjusting Parameters
With machine off hold down the
and
simultaneously and turn on the machine.
When the display shows
F.03
release the keys.
The button
to scroll the parameters while the
button enters the programming menu.
Power cycle the machine to confirm and exit programming.
Parameters default
Parameter
Display
Data set
F.03
°F
250-262.4 (not beyond)
°C
123 (1,2bar)
P.
X.X
3
l.
X.XX
0.05
d.
XX.X
2
F.04
X
0 (no change)
Preset parameters
To machine off, press the button
and turn the machine.
When the display shows the
PrS
, release the button and shut down and restart the machine.
Reset all values to the table above, for the desired temperature refer to the diagram ”temperature
range”
Summary of Contents for Alex Pid III
Page 1: ......
Page 4: ...7...
Page 5: ...8 Descrizione description...
Page 7: ...10 Schema Impianto Elettrico Alex Pid...
Page 8: ...11 Schema Impianto Elettrico Vivi Pid...
Page 10: ...13 Schema Impianto Elettrico Alex Duetto...
Page 13: ...16 1 ITALIANO...
Page 24: ...27 2 ENGLISH...
Page 37: ...40 3 DEUTSCH...
Page 52: ......