Configuration
CAN protection circuit
As an option for iPC-I 165/PCI a CAN protection circuit is available containing a
special CAN choke, a fast rectifier and a suppressor diode. The circuit keeps dis-
turbances and short spikes on CAN lines away from the electronics of the
iPC-I 165/PCI.
X9 leads the signals of the 1st bus interface to the 9 pole pin X5 and to the 9
pole sleeve X4.
Pin No.
X9
Pin No.
X4 / X5
Signal
1 1
-
2 2 CAN
Low
3 3
GND
(via
JP4)
4 4
-
5 5
-
6 6
GND
(via
JP6)
7 7 CAN
High
8 8
-
9 9
VCC
(via
JP5)
10
-
Tab. 3-4: Pin assignment X9, X4/X5
With electrically isolated bus transceivers the signals GND and VCC are also elec-
trically isolated from the GND and VCC signals of the interface.
Copyright IXXAT Automation GmbH
iPC-I 165/PCI - Manual, Version 2.3
11
Summary of Contents for iPC-I 165/PCI