Appendix
Appendix
Technical data
The following data are referred to the basic equipment of the iPC-I 165/PCI (one
Philips SJA1000 CAN controller, one bus interface according to ISO/IS 11898-2,
512 kBytes SRAM, 512kb FLASH).
Dimensions:
105
x
180
(without
connectors)
16
mm
overall
height
Weight:
approximately
160
g
Operating temperature range:
0 - 50°C
Supply
voltage:
5V
DC
±
5%
Input
current: typical 250
mA
max.
800 mA
EMC test according to:
DIN EN 55022:05.1995 Class B
DIN
EN
55022
A1/12.1995
DIN
EN
61000-3-2:03.1996
DIN
EN
61000-3-3:03.1996
DIN
EN
50082-2:02.96
EMC information
The PC/CAN interface iPC-I 165/PCI has to be used only in a CE compliant PC. The
case of the PC should be sealed up against high frequency electrical noise. Use
only shielded cables for connecting the PC/CAN interface to the CAN bus and
connect the cable shield to the connector case. The connector case has to be
sealed up against high frequency electrical noise. All unused connectors of the
PC/CAN interface card have to be closed with a cover which is sealed up against
high frequency electrical noise and ESD.
Information for programming own firmware
This manual describes how to install and use the interface in combination with
IXXAT software. If you intend to develop your own customer specific firmware,
you can get the necessary information about the hardware architecture by writ-
ing to [email protected]
Copyright IXXAT Automation GmbH
iPC-I 165/PCI - Manual, Version 2.3
14
Summary of Contents for iPC-I 165/PCI
Page 4: ......