Configuration
3.2.2 Serial RS232C interface
The serial interface can be optional assembled according to the RS232C standard.
The signals TxD, RxD and GND are connected to X3. The interface is operated by
the internal SAB C165 serial interface via the port pins 3.10 and 3.11.
Pin No. X3
Signal
1 -
2 -
3 RxD
4 TxD
5 -
6 -
7 -
8 -
9 GND
10 -
1 3 5 7 9
2 4 6 8 10
Tab. 3-6: Pin assignment X3
Copyright IXXAT Automation GmbH
iPC-I 165/PCI - Manual, Version 2.3
13
Summary of Contents for iPC-I 165/PCI
Page 4: ......