49
Sp
eci
fic
ation
s
TD-VC/-V6/-S6/-VS
TD-01/-M01TD-03/-M03TD-05/-M05 TD-1/-M1 TD-2/-M2 TD-4/-M4 TD-6/-M6 TD-8/-M8
Flow control method
Motor rpm control
Control
range
Turndown ratio
1:10
1:6
Frequency
Hz
6-60
10-60
Stroke rate*
1
spm
12-120
7-72
12-120
15-90
20-120
Reduction ratio
1:15
1:25
1:15
1:20
1:15
Stroke length
mm
1.2
2.3
1.2
2.3
6
Diaphragm effective dia.
mm
ø30
ø60
ø72
ø100
Connec
-
tion
Flange
JIS10K
Outlet
15A
25A
Inlet
15A
15A (VS:25A)
25A
Tube
VC/V6/VS
ø12×ø18
-
Union VC/V6/VS
VP16
-
Allowable liquid tem-
perature
VC/V6/VS
0-40ºC
S6
0-80ºC
Allowable ambient temperature
0-40ºC
Allowable ambient humidity
95%RH or below (non-condensing/non-vaporing)
Max suction lift*
2
1m*
3
Pump colour
RAL5002 or Munsell colour system 7PB2/11
Weight*
4
kg
VC/V6/VS
16
17
20
25
S6
20
22
25
33
*
1
Represents the stroke rate per pump head.
*
2
Represents the allowable highest lift in the operation with an open-ended discharge line and a clean water at 25ºC and
the max discharge pressure.
*
3
The TD-01/-03/-05 delivers a small amount of liquid per shot, and so air can be easily trapped in the suction line. Always
install these pumps with a smaller diaphragm in a flooded suction system to expel air from the pump and the line. See
page 24 for detail of degassing.
*
4
Represents the total weights of the pump unit plus the motor unit.
■ Inverter
Model
VF-nC3M-200_PY-A30
Power voltage
3-phase 200-240V
Power frequency
50/60Hz
Structure
IP20 self-cooling
Allowable room temperature
-10 - 60°C
Allowable humidity
5-95%RH (non-condensing/non-vaporing)
Specifications/Outer dimensions