15
In
s
tal
la
tion
Installation
This section describes the installation of the pump, piping and wiring.
Read through this section before installation is performed.
Points to be observed
Observe the following points when installing the pump:
•
Be sure to turn off power to stop the pump and related devices before installation is per-
formed.
•
If you notice any abnormal or dangerous conditions, suspend operation immediately and
inspect/solve problems.
• Do not place explosive or flammable material near the pump.
• Do not use a pump that has been damaged to avoid the risk of electrical damage or
shock.
•
Use care handling the pump. Do not drop. An impact may affect pump performance.
•
Keep the pump as level and as low as possible when it must be lifted up.
• Fumes or vapours can be hazardous with certain solutions. Ensure proper ventilation at
the operation site.
• Observe information on the appropriate drawing and specification sheet.
Pump mounting
Before installation
Check if installation doesn't adversely affect facility, surrounding equipment and the pump. Install the pump ac-
cording to the following instructions to ensure the optimum performance, safety and service.
• Allow sufficient space around the pump for easy access and maintenance.
• Select a level location, free from vibration, that won't hold liquid. Always use a level gauge.
• Install the pump as close to a supply tank in a flooded suction system.
• Avoid installing the pump:
- In direct sunlight or wind & rain.
- In a dusty/humid place.
- In a corrosive atmosphere.
- In a place where proper ventilation is not maintained.
Pump mounting