Figure 1. Conduit Seal
B. Connect static bar by cutting the high voltage cable to length, terminating the
leads, and connecting to the power supply: (see to Figure 2)
1. Strip black plastic jacket back 3¼” being careful not to nick insulation of
HV wires and strip insulation of HV wires back 1” using a wire stripper
(being careful not to nick conductor of HV wire).
2. Straighten conductors and insert into HV connector until conductor
protrudes out from the tip of connector.
3. Solder conductor to tip of connector by applying solder to exposed
conductor. Ensure that the solder does not overflow and fill neck area of tip.
4. Trim off excess conductor protruding from tip of connector.
Figure 2. High Voltage Cable Termination
5. Plug connectors into sockets labeled HV1 or HV2 on Power Supply.