17
IQ Power HLC Power Supply
& Control Station
5201259 Rev. D
E.
Connect power supply alarm output
(if used). The HLC Power Supply and
(legacy) Remote Display Module “Alarm Output” is a standard DB25 pin
connector. A maximum distance of 3 meters [10 feet] or less is recommended.
The alarm output provides a variety of relay contact outputs that indicate the
status of the power supply. The relay contacts are rated for a maximum of 1A at
30 VDC. The alarm output connector also provides a means of remote power
in. (see Figure 7).
Figure 7. IQ Power HLC Power Supply and Remote Display Module Alarm Output
Alarm Output Pin-out
Pin
Description
Pin
Description
1
Remote on/off optocoupler (-)
10
No connection
14
Remote on/off optocoupler (+)
6
No connection
19
No connection
2
Clean Bar Relay (common)*
11
Power Relay (common)*
3
Clean Bar Relay (normally closed)*
7
Power Relay (normally closed)*
16
Clean Bar Relay (normally open)*
20
Power Relay (normally open)*
8
Fault Relay (common)*
4
Fault Relay (normally closed)*
12
Power in (ground)**
17
Fault Relay (normally open)*
24
Power in (ground)**
9
Bar On Relay (common)*
13
Power in (+24V
DC)**
5
Bar On Relay (normally closed)*
25
Power in (+24V
DC)**
18
Bar On Relay (normally open)*
*30V 1A Rating on Contacts.
**1.6A Rating, Connect pins 12 & 24 in parallel and 13 & 25 in parallel.
F.
Remote On/Off Control
(if used). The “Alarm Output” connector also provides
for remote on/off control of the Power Supply. Remote on/off control is
configured with a jumper on a pin header on the main Alarm Output circuit
board. The default configuration is with remote control disabled. The remote
control can be configured “normally off” or “normally on” by the jumper setting
(see Figure 7). To access the jumpers the cover will have to be removed from the
HLC Power Supply or (legacy) Remote Display Module. Disconnect all input
power, then remove the six screws securing the cover and slowly and carefully
remove the cover.