IQ Power HLC Power Supply
& Control Station
5201259 Rev. D
D.
Connect Sensor
(if used). An IQ Power HL Sensor may be integrated into the
IQ Power system to provide feedback on static eliminating performance and is
used for the CLFB (Closed-Loop Feedback) static eliminating mode.
Use the 7.62 meter [25 foot] (black) modular cable supplied with HLC. Longer
cables (not supplied) are available. Cables for Sensor Interface must be IQ
Power 8-conductor modular cables with RJ-45 connectors wired “crossover”
(reference color: black, Figure 4).
The modular cable plugs into one of the connectors labeled “SI COMM 1” on
Sensor Interface and into the “PS COMM 1” connector on HLC Power Supply.
(see Figure 6)
The second modular cable plugs into the other connector labeled “SI COMM
1” on Sensor Interface and into one of the connectors labeled “POWER &
COMM” on the Control Station.
Route modular cable clear of moving machine parts and protect it from
abrasion. Secure using nylon wire ties (not supplied). Do not over-tighten wire
tie.
If there is an excess of modular cable, if possible, cut modular cable to length and
re-terminate using an RJ-45 connector installed with the same “polarization” as
connector removed (note rib / wire color code to modular connector).
See instructions included with IQ Power HL Sensor for sensor installation.