5.0 Technical Specifications
Standards:
ISO 6858
Aircraft ground support electrical supplies - general requirements
BS 2G 219
General requirements for ground support electrical supplies for aircraft
SAE ARP 5015
Ground equipment – 400 Hz ground power performance requirement
MIL-704F
Aircraft electric power characteristics
DFS 400
Specification for 400 Hz aircraft power supply
EN2282
Aerospace series characteristics of aircraft electrical supplies
EMC & Safety standards
Please refer to the declaration of conformity, chapter 1
Solid State Ground Power Unit:
Input:
Model
Amps
(0.8)
Amps
(1.0)
Hertz
Voltage
Max.
Fuse
Line
Current
Dist.
PF at
nominal
load
30SX240
38 A
49 A
45-65
400 ± 15%
32 A
41 A
45-65
480 ± 10%
160 A
< 12%
> 0.97
26 A
33 A
45-65
600 ± 15%
45SX240
58 A
70 A
45-65
400 ± 15%
48 A
59 A
45-65
480 ± 10%
160 A
< 10%
> 0.99
38 A
47 A
45-65
600 ± 15%
60SX240
75 A
96 A
45-65
400 ± 15%
63 A
80 A
45-65
480 ± 10%
200 A
< 9%
> 0.99
50 A
64 A
45-65
600 ± 15%
90SX240
112 A
141 A
45-65
400 ± 15%
94 A
117 A
45-65
480 ± 10%
200 A
< 5 %
1
75 A
94 A
45-65
600 ± 15%
Phase
ABC or CBA
Rectification
Inrush current
12 pulses
None
Power interruption
20 ms