6.1
Using the Display/Keypad
To enable a smooth and easy operation, the operator control panel has a simple layout. The LED display
is located at the top. It is used to provide information during operation / service / maintenance. It either
shows operational data, warnings or failure information in plain text combined with a time stamp and a 4
digit code which can be used in combination with the manual to show more detailed information on the
reported message.
Note!
Please refer to section
6.0
for the various push button layouts.
*
Warning may arise during operation for the following issues:
Cable 1 Temperature Too High / Cable 2 Temperature Too High
Neutral Conductor Rupture Output 1 / Neutral Conductor Rupture Output 2
EF Signal Drop Out – Output 1 / EF Signal Drop Out – Output 2
Aircraft Connector not inserted – Output 1 / Aircraft Connector not inserted – Output 2
The unit will report an error if only one output is active and a failure signal present, otherwise it will
issue a warning about any of the above issues.
Fig. 6.1.1 Display / Operator panel
Navigation keypad equipped
with
4 arrows
and
1 select
push
button.
3 x LED indications.
Blue LED:
As soon as the main power is
connected and the unit is switched
on, this LED is illuminated.
Yellow LED:
If any warnings are reported, this
LED is illuminated to draw the
operator’s attention. *
Red LED:
This LED is illuminated as soon as
the unit shuts down due to a failure.
Single push button, for
Start/Stop of the unit.
The 400Hz LED turns
“Green”
when the unit is supplying
power at the output.
The push button also functions