Page 4-4
Revised 1/05
ITW Dynatec c. 2004
DYNAMINI ASU Manual #20-25
Default Settings of the Controller
Default settings are the manufacturer’s preset values to which the system will return if the Dyna-
mini tempearture control is subjected to an internal memory reset. While you can change your pro-
grammed values to anything within the system’s limits, the default settings cannot be changed.
To cause an internal memory reset (ie, to restore the defaults) of a temperature zone, turn that tem-
perature zone ON and then OFF.
Defaults
·
Temperature setpoint for each zone: 93
°
C (200
°
F).
·
Sequential Startup: SSO (OFF)
Helpful Tips for the User
·
When the ASU is turned on, all temperature setpoints and other operating parameters will
be exactly where they were when the ASU was turned off.
·
When the ASU is turned on, all system heaters go on unless they have previously been set
below 40
°
C (100
°
F).