NOTICE!
Property damage due to improper transportation!
–
Do not lift the pump by its bearing case or gear case.
–
Ensure that the pump unit is not overly tensioned when it is
lifted.
–
Ensure that the lifting tackle cannot damage pipelines or units
when lifting, possibly use a lifting frame (
dimensional draw-
ings, operating instructions for pump system).
–
Make personal safety equipment available.
–
Observe statutory or other safety and accident prevention regu-
lations.
n
Pump switched off and safeguarded against being switched on again.
n
Pump pressure-free.
n
Pump completely emptied and rinsed.
n
Pump disconnected from the electrical system.
n
Inlet and outlet-side valves shut and safeguarded against unintentional
opening.
n
Pump cooled.
n
Coupling guard dismantled.
n
For coupling with spacer: Remove spacer.
Remove the pump from the system.
7.4.2 Return pump to the manufacturer
Repair work may only be executed if the declaration of no objection
Chapter 9.2 ‘Declaration of no objection’
n
Pump removed.
n
Pump cooled.
n
Pump cleaned.
n
All flanges and screw bores plugged.
1.
Only return pump or individual components to ITT Bornemann GmbH with
a completed declaration of no objection (
Chapter 9.2 ‘Declaration of no
).
2.
Depending on the desired repair, observe the required measures for return
in accordance with the following table.
Prerequisites:
Procedure:
Prerequisites:
Maintenance and repairs
65
Type SLH-4U
0
3
/20
20
JP Rev. 1