5.5.3 Taking into account peak height changes
With cold alignment take into account peak height changes under the influence of
the operating temperature according to the following figures. As soon as the
pump system has reached the operating temperature following start-up, it is nec-
essary to check the alignment (hot alignment) once again.
To determine the material model of the pump
Pump data sheet.
Abbreviation
Meaning
Tm
Temperature median value Tm = (T2-T1)/2
T1
Ambient temperature
T2
Medium temperature
ΔH
Peak height change
Fig. 13: Peak height change
No.
Size
1
SLH 80, SLH-4G 10xx, SLH-4U 10xx
2
SLH-4G 20xx, SLH-4U 20xx
3
SLH 125
4
SLH-4G 30xx, SLH-4U 30xx
5
SLH-4G 40xx
6
SLH 180
Explanation of the abbreviations
Peak height change
Installation and connection
35
Type SLH-4U
0
3
/20
20
JP Rev. 1