Common Commands
Copyright © Itech Electronic Co., Ltd.
62
Relevant Command
*ESE *ESR? *PSC *STB?
*STB
This command can query the Status Byte register. After executing this
command, the bit6 of status byte register will be reset to 0.
Bit Position
6
5
4
3
Condition
RQS ESB
MAV QUES
The descriptions of Parameter in the table are as follows:
RQS: request for service
ESB: Event summary bit
MAV: Message available
QUES: One or more questionable event register is reset
Query Syntax
*STB?
Parameter
None
Returned value
<NR1>
Relevant Command
*CLS *ESE *ESR
*SAV
This command stores the present state of the electronic load to a specified
location in memory. These parameters including current settings, voltage
settings, operation mode and so on.
Command syntax
*SAV <NRf>
Parameter
0~9
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com