  Dry Filter Spraybooth Installation and Maintenance Instructions

 

 

 

 

 

 

 
 

 

 
In order to comply with the requirements of CE marking, all Spraybooths must now be fitted with a facility for an 
emergency stop within easy reach of the operator.  

Airflow

  will be pleased to quote for the supply of a suitable 

emergency stop wire kit, now available to meet the requirements of this regulation.  Please contact our Sales 
Department for further information. 
 

13   

Fitting of Filters

 

 

Airflow

 Dry Filter Spraybooths are fitted with either Paper-Type Filter Medium or Open-Weave Filter Medium.  Please 

identify which type of Filter Medium has been supplied with your Spraybooth and follow the appropriate instruction 
paragraph below. 
 
If you are unsure as to which type of filter has been supplied, please check one of the filter support frames.  If the frame 
is fitted with a 50mm by 50mm weldmesh panel then your Spraybooth is to be used with Open-Weave Type Filter 
Medium.  If the apertures are open, without the weldmesh panel, then this Spraybooth can only be used with the 
concertina Paper-Type Filter Medium. 
 
FITTING PAPER-TYPE FILTER 
Remove the filter paper from the box. First begin by stretching out the filter paper on the floor to the correct pleats per 
metre.  Measure the width of filter paper appropriate to the width of your Spraybooth and add to this length an extra 
250mm.  Cut the paper this length.  At the left and right hand side of each filter paper slot is an angled filter paper clip.  
Gather together the first three or four corrugations at the left-hand side of the filter paper and insert them into the filter 
paper clip.  This will now hold the left-hand side of the filter paper.  Stretch the filter paper carefully across the width of 
the Booth until you reach the right hand side.  Now gather together the remaining corrugations and insert into the right 
hand paper clip.  Repeat this operation for the lower filter paper slot and the installation of the filter medium is now 
complete. 
 
FITTING OPEN-WEAVE FILTER MEDIUM 
Open-Weave Filter Medium is supplied on a roll and must be fitted into the Spraybooth with the green surface facing 
towards the operator.  Unroll a suitable length of filter medium on the floor and cut to width of the Spraybooth.  At the 
left and right hand side of the Spraybooth filter slot is a filter medium clamp plate secured to the Spraybooth with self-
tapping screws.  Remove both filter clips and stretch the filter medium across the face of the Spraybooth slot.  Once in 
position, replace the two filter medium clips by screwing the self-tapping screws through the Filter Medium.  Repeat 
this operation for the lower filter medium slot and the installation of the Spraybooth filter is now complete. 

 

14   

Commissioning

 

 
Commissioning of 

Airflow

 Dry Filter Spraybooths is a simple operation. 

 

Summary of Contents for DEC2.2

Page 1: ...DRY FILTER SPRAYBOOTH INSTALLATION MAINTENANCE INSTRUCTIONS Scott Sargeant Woodworking Machinery Ltd 1 Blatchford Road Horsham West Sussex RH13 5QR ENGLAND Tel 44 0 1403 273000 W b ...

Page 2: ......

Page 3: ...entification of Working Areas 4 Delivery and Handling 5 Inspection 6 Warranty 7 Assembly and Installation 8 Exhaust Ducting 9 Noise 10 Electrical Data 11 Electrical Connections 12 Siting of Electrical Controls 13 Fitting of Filters 14 Commissioning 15 Operation 16 Maintenance 17 Servicing 18 Spare Parts 1 1 1 2 3 3 3 4 4 4 5 5 6 6 7 7 8 9 ...

Page 4: ......

Page 5: ... above information products manufactured for supply within the EEC will have a CE Mark affixed which indicates compliance with the directives listed on the declaration of conformity contained within this document To enable the identification of spare parts please refer to the tabulated information contained within section 18 of these instructions 2 Uses Of the Machine Normal use of an Airflow Spra...

Page 6: ...n Weight Individual Panel Weight Pack of Filter Paper DF2 2 310 88 25 10 DF3 3 375 90 25 10 DF4 0 430 104 25 10 DF4 4 510 2 x 88 25 10 DF5 5 570 2 x 90 25 10 DF6 6 630 2 x 90 25 10 DFB1 1 175 72 25 10 DFB2 2 240 88 25 10 DEC2 2 260 88 25 10 DEC3 3 325 90 25 10 DEC4 0 380 104 25 10 DEC4 4 460 2 x 88 25 10 DEC5 5 520 2 x 90 25 10 DEC6 6 580 2 x 90 25 10 DHC2 2 190 88 25 10 DHC3 3 225 88 25 10 DHC4 0...

Page 7: ...cement of any parts and associated carriage costs It does not cover the labour to fit parts or the cost of removing refitting or any secondary losses Any warranty claim must be immediately notified to Airflow No repair work is to be conducted without prior agreement Any claim or defect arising from incorrect installation inadequate maintenance or abuse of the equipment however caused is not covere...

Page 8: ...hing Limited on the suitability of intended ductwork systems Please contact our Sales Department for further advice 9 Noise Please refer to the tables over to obtain information of test results obtained from typical Airflow Spraybooth installations Please Note Specific individual noise levels should be obtained following installation of your Spraybooth as it is impossible for Airflow to predict th...

Page 9: ... supply cables should be connected securely to the appropriate electrical motor terminals in accordance with the diagrams in the motor terminal box and with the information given on the motor rating plate All cables must be of adequate size to prevent any drop in supply voltage The appropriate cable gland must be fitted to the terminal box and tightened and secured against ingress of duct dampness...

Page 10: ... of your Spraybooth and add to this length an extra 250mm Cut the paper this length At the left and right hand side of each filter paper slot is an angled filter paper clip Gather together the first three or four corrugations at the left hand side of the filter paper and insert them into the filter paper clip This will now hold the left hand side of the filter paper Stretch the filter paper carefu...

Page 11: ...validation of your 12 month Parts Warranty DAILY Check the condition of the Filter Medium If a Filter Loss Gauge is fitted ensure that once the Booth is running the pressure drop across the filter medium is within recommended limits Ensure that all fans are operating correctly and listen for any unusual noises or vibration which may indicate a deteriorating condition of the drive belts and or an a...

Page 12: ...late using the M16 nuts until it is possible to deflect the belt by 10 15mm as it enters the fan housing with moderate finger pressure Caution Do not cover tighten drive belts as premature wear of motor bearings shaft bearings and other drive components will result 7 Replace belt guard 8 Test run the Fan REMOVAL AND REPLACEMENT OF COMPLETE CARTRIDGE ASSEMBLY 1 Isolate the supply to the Spraybooth ...

Page 13: ...hly without noise or vibration Airflow provides a national network of trained service engineers Each service vehicle is equipped with a considerable range of genuine spares We would strongly recommend that to maximise the performance and longevity of your Our own service personnel carry out airflow Spraybooth that service work Please Note It is a condition of your 12 month Warranty that your Spray...

Page 14: ...lare under our sole responsibility that the spray booth referred to in these instructions taking into account the state of the art comply with or are designed and constructed so far as is possible to comply with the relevant essential Health and Safety requirements as indicated in the technical file and contained within EEC Directives Machinery Directive 2006 42 EC Electromagnetic Compatibility Di...

Reviews: