Dry Filter Spraybooth Installation and Maintenance Instructions
9
1. Slide the cartridge arm into the fan casing until the shaft locates in the fan casing hole. Lower the cartridge by
approximately 50mm into position.
2. Replace the four mounting bolts, ensuring that that the identical shims are placed in identical respective positions.
3. Tighten these bolts to 30Nm (22lbs/ft.).
4. It is now necessary to visually check from inside the Spraybooth that the fan impeller shaft is perfectly central within
the fan casing aperture. If the shaft is not exactly in the centre of the hole, adjust the shims under the bolts until it is
exactly central with an even gap all the way around.
5. Fit a new flinger seal onto the Fan shaft.
6. Replace the impeller and tighten the impeller securing belt to a torque of 30Nm.
7. Replace the fan finger guard.
8. Replace the filter medium.
9. Test run the fan, check its direction of rotation and check that it operates smoothly without noise or vibration.
Airflow
provides a national network of trained service engineers. Each service vehicle is equipped with a considerable
range of genuine spares. We would strongly recommend that to maximise the performance and longevity of your
Our own service personnel carry out airflow Spraybooth that service work
.
Please Note: It is a condition of your 12-month Warranty that your Spraybooth is serviced every 6 months. Please
contact
Airflow
Sales Department to arrange for your service visits.
In addition to standard servicing
Airflow
are also able to provide a complete performance, environmental and COSHH
assessment service. Please contact our Sales Department to discuss your requirements.
18
Spare Parts
Please quote the following information when ordering spare parts.
Your Company Name
e.g.
A. Smith Limited
Model Number
e.g.
DF3.3
Serial Number
e.g.
14459
Inspection / Despatch Date
e.g.
11/10/95
Airflow
carry large stocks of all spare parts and can arrange same day despatch for orders received before 3pm Monday to Friday.
Please Note: The performance of your
Airflow