28
INSTALLER
Controller board
To remove and restore the controller board (1):
- squeeze the snap spacers to release the board;
- remove the connectors from their plugs;
- replace the board and replace the cables as before.
Flame controller board
To remove and restore the flame controller board (1):
- undo the screws securing the board and take it off its
mount;
- remove the connectors from their plugs;
- replace the board and replace the cables as before.
Room thermostat sensor
To remove and restore the sensor (1):
- disconnect the faston connectors from their clips;
- release the sensor from its bracket;
- replace the part and fit the new one in reverse order.
Fuse burnt out
If the appliance does not turn on again following a short
circuit, check the fuse as follows:
- carefully detach the outer cap (1);
- remove the fuse (2) and check it; if it is burnt or the
filament is broken, replace it with another rapid fuse:
1A-250 V.
se
se
se