25
INSTALLER
Minimum pressure adjustment
always set the minimum pressure only after having
first set the maximum pressure!
With the appliance running at minimum power, and the
thermostat knob turned to pos. 1.
- Check that the minimum pressure values match those
given in the table.
- Use the minimum flow rate regulator screw on the right
side of the gas valve.
Turn the regulator CLOCKWISE to decrease the pressure
and COUNTERCLOCKWISE to increase it.
Once the settings have been made, seal both the
pressure and minimum flow rate regulators with a drop
of paint, then disconnect the pressure gauge from the
pressure port and turn in the screw.
Routine maintenance must be run once a year to ensure
that the appliance runs safely and efficiently throughout
its service life. Doing so also reduces consumption and
polluting emissions.
Note that the appliance must be serviced by the
manufacturer's Technical Service or a qualified
technician who will clean the burner and the ignition and
flame detector electrodes and check the appliance's
settings, according to need.
Preliminary operations:
- Disconnect the electrical power supply by pulling the
power socket from the plug on the appliance itself or
setting the master switch to OFF;
- close the gas cock.
- wait for the convection heater to cool down completely;
MODEL
18
30
BUTANE
nom. / red.
28,8 / 14,8
28,7 / 14,8
PROPANE
nom. / red.
36,8 / 18,8
36,7 / 18,8
mbar
mbar
45
28,6 / 14,8 36,5 / 18,8 mbar
sc/sV
se
se
routine maintenance