19
INSTALLER
The equipment is supplied completely cabled and with
a mains plug.
You need only make up a HAR H05 RRF power cable
with at least 1 mm2 cross section wires, assembled to
the loose plug at one end and to the plug or master
switch at the other.
A proper earth connection is obligatory. The
manufacturer is not liable for any damage caused by
unearthed equipment.
For all electrical work, refer to the wiring diagram
included in this booklet
Provide a mains disconnection device upline of the
power cable (omni-polar disconnector or plug), with a
contact air gap of at least 3 mm.
The polarities must be observed: blue is NEUTRAL and
yellow/green is EARTH.
Strip the earth wire at least 2 cm longer than the other
two wires.
Do not use the gas or water pipes to earth the appliance.
Ensure that the heater is configured for your gas supply;
this information is given on the nameplate mounted to
the heat exchanger jacket.
Connect the heater to the gas supply line with the union
and cock included with the appliance, using a rigid pipe
and regulatory fittings.
The fitting on the appliance itself is a 3/8” M union per
UNI ISO 7/1.
If the gas supply is on the right side of the heater, use a
nipple to resolve any clearance issues.
Once you have completed the gas line hookup, run the
tightness tests specified in the applicable installation
regulations.