7. TROUBLESHOOT GUIDE
IRREGULARITY
CAUSE
PROCEDURE
Machine does not start
Machine unplugged.
Check and plug in.
Front lid is not closed well.
Check front lid closure.
Compressor starts and
Watercooled machine:
Open water tap.
then stops after a few
water does not circulate.
seconds without ice cream
being thick
Check that hose is neither
squashed nor doubled up.
Aircooled machine:
Check that rear of machine is
air does not circulate
at least 50 cm from wall.
Clean condenser from
obstructions.
After 30 minutes processing
No gas.
Check leakage and weld.
mix has not frozen and the
machine returns to Stop
Pressure switch has broken
Check connection
down.
and replace, if need be.
Mix in drip drawer
Stuffing box missing
Install if missing.
or ruined.
Replace if ruined.
Ice cream comes out
Gasket missing or not
Check and fix or replace.
from behind front lid
properly installed.