STARGEL
Stargel - 2018/04 - rev. 03
- 13 -
EN
2. INSTALLATION
2.1 ROOM NECESSARY TO THE MACHINE USE
The machine must be installed in such a way that air can freely circulate all around.
Rooms for the approach to the machine must be left free in order to enable the operator to act
without constraint and also to immediately leave working area, if need be.
The minimum approach room to working area should be at least 150 cm in consideration of space
taken by opened doors.
ATTENTION
MACHINES WITH AIRCOOLED CONDENSER
must be installed
NO CLOSER THAN
50 CM TO ANY WALL
in order to allow free air circulation around the condenser.
NOTE
An insufficient air circulation affects operation and output capacity of the machine.
2.2
WATER SUPPLY CONNECTION
The machine must be connected to running water which pressure must not be higher than 0,8
MPa (8 bars).
By aircooled machines, water connection for drinking water (for machine wash) is placed under
the machine.
By watercooled machines water connections (for machine wash and gas cooling) are placed on
upper panel.
2.3 MACHINE WITH AIRCOOLED CONDENSER
Machines with aircooled condenser must be installed no closer than 50 cm to any wall in order
to allow free air circulation around the condenser.
NOTE
An insufficient air circulation affects operation and output capacity of the machine.
Fig. 3
150 cm
50 cm air only