3.5 Upgrade Card
The Upgrade Card allows you to extend the functional range
of the automatic swing door drive unit is 9100. During
the installation of the Upgrade Card, information between
the control unit and the Upgrade Card is exchanged and
assigned. The desired function can be used as long as the
Upgrade Card is installed in the drive system.
• The first installed Upgrade Card becomes the container
module. The functions of additional Upgrade Cards
are saved in the container module. Each control unit
features only 1 container module.
• The status of the Upgrade card is indicated by 3
integrated LEDs.
3.5.1 Upgrade Card Full Energy – blue
The Upgrade Card Full Energy allows you to make use of
the full setting range of the opening and closing speed
parameters as well as the opening and closing torque. It can
be used for 2-panel systems.
3.6
Accessories
In addition to an extensive range of ISEO accessories, many
activators, locking devices, safety sensors and accessories
of other manufacturers are available and could be used
together with the drive unit IS 9100.
ISEO cannot guarantee the compatibility with devices from
other manufacturers. If those devices are always used, the
full functional range of the drive units may not be available
or the devices may not function properly.
The drive unit or the connected device may also become
damaged.
The operator can provide a maximum 1.5 A with 24 V DC for
external consumers. Should more be required (even if only
temporarily), an external power supply is to be used in order
to prevent a malfunction of the drive unit.
3.6.1 Activator
In general, the following types of devices are activators:
radar motion sensors, passive infrared motion sensors,
pushbuttons, switches, sensor buttons, radio, IR-receivers,
access control systems, telephone and intercom systems.
Activator, inside outside, night/bank and intercom system
may be connected to the device. The activator inside is
usually found inside a building or room. The activator outside
is found on the outside of a building or room. The activator
night/bank is installed on the outside and often designed as
a card reader or key switch button.
Minimum requirements:
Operating voltage when supplied by the drive unit:
24 V DC +/- 5 %
Pulse duration:
min. 200 ms
Potential-free output:
(in case a signal input internal is used,
external detector or night/bank)
Energized output (telephone systems):
max. 24 V DC/AC +/- 5 %
3.6.2 Locking device
In general, the following types of devices are locking devices:
electrical door opener (E-opener), motor locks, multi-point
locking device with response contact, holding magnets.
Motor locks without a locking response can be directly
connected to the drive unit if the locking time is less than
4 seconds. In order to ensure the safe operation of the
combined drive unit and locking device, the locking device
must meet the following specifications:
Minimum requirements:
Operating voltage when supplied by the drive unit:
24 V DC +/- 5 %
Operating voltage with an external supply:
max. 48 V DC/AC
Load of the contact relay locking:
max. 1 A
Switch-on time electrical door opener:
min. 30 %
Switch-on time motor lock:
100 %
IS 9100
—