2.
1.
1
2
3
5 mm
5. Installing the drive unit
Secure the workspace against trespassing. Dropped
parts or tools may result in injuries.
The described procedure is only an example.
A different procedure might be preferable due to structural
or local conditions, available tools or other circumstances.
Requirements
• A 230 V/50-60 Hz connection with a fuse protection of
16 A must be available at the place of installation.
• The door panel must be in a sound mechanical
condition and smooth-running.
Standard tightening torques
M 5 ......... 5 Nm
M 6 ...... 9.5 Nm
M 8 ....... 23 Nm
M 10 ..... 46 Nm
M 12 ..... 79 Nm
Required tools
2.5 mm
6
mm
2.5 mm insulated
6
mm
5 mm
13 mm
1/2/3
5.1 Removing the drive unit from the mounting plate
1.
Loosen the 8 fastening screws.
2.
Unplug the 230 V connector.
3.
Disconnect the drive unit from the mounting plate.
Use a screwdriver as a lever between the drive unit and
the base plate.
|
4.
Place a piece of wood or similar underneath the drive
unit so that the connecting part cannot become loose.
5.2 Mounting the receiver (optional)
1.
Connect the receiver, if you need.
For more information on installation, refer to its
mounting instruction.
57
57a
14
2
3
14
1
3
1
15
17
+ 24 V
Pulse
0 V
0 V
1
IS 9100
—
13
ISEO