SET
SET
SET
SET
F
F
F
F
0
0
0
0
F 1X
F
F
F 1X
1X
1X
.
TO SEE THE MAXIMUM TEMPERATURE
1.
Push and release the button.
2.
Message displayed: “HI” + max. temperature reached.
3.
By pushing the button
or by waiting for 5 seconds the normal temperature will be displayed again.
TO SEE THE SET POINT
1.
Push and release the button
SET
: set point will be immediately displayed;
2.
To go back to the temperature, wait for 5 seconds or push
SET
again.
TO CHANGE THE SET POINT
1.
Keep button
SET
pushed for about 2 seconds.
2.
Set point will be displayed, and the LED
°C
will start flashing;
3.
To change the value, push buttons and
4.
To record the new set point, push button SET or wait 15 seconds to leave programming.
TO START A MANUAL DEFROST CYCLE.
To start a defrost cycle push button for at least 2 seconds.
TO LOCK THE KEYBOARD
1. Keep buttons and pushed for a few seconds, until the flashing word “POF” is displayed.
2.
At this point, the keyboard is locked: you can only display the set point, the max. and min. temperature,
3.
If a button is kept pushed for more than 3 seconds , the word “POF” will appear.
TO UNLOCK THE KEYBOARD.
Keep buttons and pushed for a few seconds, until the flashing word “POn” is displayed.
ON/OFF FUNCTION
Push ON/OFF button for 2seconds: the device will display “OFF”.
In this configuration, all loads and controls are disabled.
To go back to ON, push again the button for 2 seconds.