14. ADJUST THE DRAINAGE VALVE FOR THE BLOWER
If there is some air comes out from the water lead pipe which connects with the drain valve when the blower
work, there might been some debrises etc. cause the malfunction, this time you need to adjust the black valve in
the drain valve as follows
1, Open the drain valve and take out the black valve and check for debrises.
2, Use a clamp to hold the nut, and at the same time, use a screw driver to wring the screw tightly a little
than before. Note :There must be a gap of at least 1mm.
3, After adjusting this, insert the black valve into the drain valve and close the drain valve.