Model2310 Ver.14.0
9
400V, 3X16AMP
(
when any/all high-speed pumps or blower is running, the heater enable
)
1, 2, 3 BRN – Live
BLU – Neutral
Remove the black wire J51-J88
Remove the black wire J52-J62
Relocate the Black wire from J60-J36 to
J60-J45
Relocate the Black wire from J41-J12 to
J41-J79
(b) Dip Switch Reference
A1 Test mode (normally Off)
A2 In ―ON‖ position, add one high-speed pump (or blower) with heater
A3 In ―ON‖ position, add Two high-speed pump (or1HS Pump and blower) with heater
A4 In ―ON‖ position, add Four high-speed pump (or3HS Pump and blower) with heater
A5 In ―ON‖ position, enables Special Amperage Rule B, 1phase Two pumps
In ― OFF‖ position, enables Amperage Rule A, Three phases 3*16A / 1*32A: two pumps+1blower
A6 Persistent memory reset (Used when the spa is power up to restore factory settings as determined by
software configuration)
software configuration)
A2,A3,and A4
work in combination to determine the number of high-speed devices and blowers that can run
before the heat is disabled, I.e. A2 and A3 in the On position and A4 in the OFF position will allow the heater to
operate with up to 3 high-speed ( or two HS pumps and Blower) running at the same time. Heat is disabled when
the fourth high-speed pump or blower is turned on.
Note: A2/A3/A4 All off = No heat with any high-speed pump or blower.
Assignable Dip Switches
A7 In ― ON‖ position, enables a 5-minute cool down for same gas heaters( Cooling Time B)
In ― Off‖ position, enables a 1-minute cool down for electric heaters (Cooling Time A)
A8,A9,A10 Undesignated switches are not assigned a function.