background image

 

Model2310 Ver.14.0 

                                                                                                 

14 

 

Note: 

If power is interrupted to the system, Time-of-Day will be maintained for several days.

 

Main Filtration 

Using the same navigation and adjustment as Setting the Time, Filter Cycles are set using a start time and a 

duration. Each setting can be adjusted in 15-minute increments. The panel calculates the end time and displays it 

automatically. 

 

 

 

 

 

 

 

Filter Cycle 2 - Optional Filtration 

Filter Cycle 2 is OFF by default. 

Simply navigate to the Filter Cycle 2 line by pressing the Right Navigation Button, and when ―NO‖ is 

highlighted, press Up or Down to toggle Filter Cycle 2 on and off. When Filter Cycle 2 is ON, it can be 

adjusted in the same manner as Filter Cycle1 by navigating to the right. It is possible to overlap Filter Cycle 

1 and Filter Cycle 2, which 

will shorten overall filtration by the overlap amount. 

Note: our factory delivered setting is the Filter cycle 2 is on, and the filter cycle time is Filter cycle1 
The default is “FILTER 1” is 6:00AM to 10:00AM, “FILTER 2” is 6:00PM to 10:00PM) 

Purge Cycles 

In order to maintain sanitary conditions, as well as protect against freezing, secondary water devices will purge 

water from their respective plumbing by running briefly at the beginning of each filter cycle. If the Filter Cycle 1 

duration is set for 24 hours, enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is programmed to 

begin. 

Invert Panel 

Selecting Invert Panel will flip the display and the buttons so the panel can be easily operated from inside or 

outside the hot tub. 

Lock setting 

The control can be restricted to prevent unwanted use or temperature adjustments. Locking the Panel prevents 

the controller from being used, but all automatic functions are still active. Locking the Settings allows Jets and 

other features to be used, but the Set Temperature and other programmed settings cannot be adjusted. Settings 

Lock allows access to a reduced selection of menu items. These include Set Temperature, Invert, Lock, Utilities, 

Information and Fault Log. They can be seen, but not changed or edited.

 

 

 

 

 

 

 

 

 

Summary of Contents for Trinidad2200

Page 1: ...den by IQue Sweden AB Grustagsgatan 13 254 64 Helsingborg Sweden Here is your manual please read and follow the instructions carefully Diamond Version www iquehottubs com Ver 14 0 December 2013 Thank...

Page 2: ...____8 7 INITIAL START UP SPA COVER BASKET LIFTER___________________33 8 START UP CARE________________________________________________35 9 WATER CHEMISTRY______________________________________________3...

Page 3: ...nd improve our spa products without prior notice This may result in minor variations between this manual and your spa Thank you SAVE THESE INSTRUCTIONS 1 SAFETY INSTRUCTIONS IMPORTANT READ FOLLOW AND...

Page 4: ...inside the spa or if you are wet Do not permit any electric appliance such as a hair dryer light radio telephone or television within 5 feet 1 5m of the spa g WARNING To reduce the risk of injury i Wa...

Page 5: ...sure the water temperature with an accurate thermometer before entering the spa Tolerance of water temperature may vary and regulating devices may differ as much as 5 F 3 C d Spa water temperatures fo...

Page 6: ...r 40 C can be hazardous to your health c Long exposure in water at higher temperatures can cause high body temperature Symptoms may include dizziness drowsiness fainting and nausea and reduced awarene...

Page 7: ...indoors or outdoors IMPROPER INSTALLATION MAY RESULT IN EQUIPMENT DAMAGE AND VOID THE WARRANTY Surface and Pad Requirements Place your new Spa on a 4 10cm thick reinforced CONCRETE PAD Ensure the conc...

Page 8: ...r Selection The Equipment Type column does not include the circulation pump for Silver series A jumper in the equipment control box configures the mode In the HC 32 AMP 230 V or 2 and 3 phases Mode th...

Page 9: ...etailer 6 1 MAINS CONNECTIONS a Services Configuration Options 1 or 3 phases Balboa System BP2001G1 PN 56389 01 Configuration Setting 2x 2 speed pump 1x Circ Pump 1x Blower The default is FILTER 1 is...

Page 10: ...ses 3 16A 1 32A two pumps 1blower A6 Persistent memory reset Used when the spa is power up to restore factory settings as determined by software configuration software configuration A2 A3 and A4 work...

Page 11: ...initial start up sequence the control will enter Priming Mode and display a Priming Mode screen Only pump icons appear on the priming mode screen The system will automatically return to normal heating...

Page 12: ...t measured spa temperature displayed is current only when the pump has been running for at least 2 minutes The only item that can be changed on the left side of the Main Screen is the Set Temperature...

Page 13: ...tings with independent set temperatures The specific range can be selected on the settings screen and is visible on the main screen in the upper right corner of the display These ranges can be used fo...

Page 14: ...peed at the same time the circ pump will start to work with the pumps or blower when the pumps or blower turn off the circ pump will keep working for up to 1 minute then stop Time of day Setting the t...

Page 15: ...Filter cycle1 The default is FILTER 1 is 6 00AM to 10 00AM FILTER 2 is 6 00PM to 10 00PM Purge Cycles In order to maintain sanitary conditions as well as protect against freezing secondary water devi...

Page 16: ...l require more than an hour it may be best to simply shutdown power to the spa Utilities The Utilities Menu contains the following A B Temps When this is set to On the temperature display will alterna...

Page 17: ...ttom of the screen Software ID SSID Displays the software ID number for the System System Model Displays the Model Number of the System Current Setup Displays the currently selected Configuration Setu...

Page 18: ...automatically then you press the lights button turn off it then turn on it stay red color then you keep turning off and turn on they will stay different colors every time and after 7 times they get ba...

Page 19: ...tential freeze condition has been detected or the Aux Freeze Switch has closed All water devices are activated In some cases pumps may turn on and off and the heater may operate during Freeze Protecti...

Page 20: ...e control panel is not receiving communication from the System Call for Service Test software installed The Control System is operating with test software Call for Service F or C is replaced by T The...

Page 21: ...g the Preferences Menu Reminder Messages can be chosen individually by the Manufacturer They may be disabled entirely or there may be a limited number of reminders on a specific model The frequency of...

Page 22: ...ol of hot tubs Check the BWA CONTROL YOUR TUB Balboa manual Step 1 Download the app to your smart device from either the Google Play or the iTunes store Once you have it loaded on your phone you are r...

Page 23: ...device iOS would be similar Make sure you are near your tub Go to your Wi Fi settings screen and look for the BWG SPA network it will be named similar to BWGSpa_12345 In our example it is BWGSpa_0E60...

Page 24: ...ternet network from your tub is to try and connect to it with your smart device next to the tub Open a browser window and connect to the Internet or any other app that connects to the Internet While s...

Page 25: ...g up your Local Home Wi Fi is a one time process Once connected you will not need to change your settings again unless your network SSID changes You are now ready to connect your tub to your local hom...

Page 26: ...Model2310 Ver 14 0 25...

Page 27: ...Model2310 Ver 14 0 26...

Page 28: ...Model2310 Ver 14 0 27...

Page 29: ...Model2310 Ver 14 0 28...

Page 30: ...Model2310 Ver 14 0 29...

Page 31: ...Model2310 Ver 14 0 30...

Page 32: ...he package adhered on one white board fixed on the frame in pump area in case any fuse in box is burnt can be replaced in time When the spa delivered setting power services configuration is 2phase or...

Page 33: ...Model2310 Ver 14 0 32 6 3 The power cable cap There are both power cable caps on the corner shirt you can use a drill machine to drill the suitable hole for the power cable...

Page 34: ...handle is open Spas with 1 pump will include 2 valves and spas with 2 pumps will include 2 valves Note a circulation pump will include 2 valves The valves are in open position upon delivery see pictur...

Page 35: ...ould install the back skirt panel that side faces to the control box panel side one this side shirt we have drilled the holes for the fixing screws just need to use the screw to fix the spa cover bask...

Page 36: ...bles do as follows Turn the power off and follow the instructions on last page in this Manual WARNING DO NOT ALLOW THE PUMPS TO RUN FOR MORE THAN 1 one MINUTE WITHOUT WATER FLOWING FROM THE JETS PUMPS...

Page 37: ...ll jets installed in the foot well walls turn off the jet pumps and blower check for small bubbles coming out from the small jets 15 To conserve energy and ensure your spa is ready for use place the t...

Page 38: ...to turn when the spa pump is on high speed This is normal and is caused by the high rate of water flow and pressure present in the valve Two pump systems have two valves and one pump systems have one...

Page 39: ...OL All water has a PH value This value measures the acid to alkaline relationship from 14 point scale A reading of 7 0 is considered neutral while a lower reading is considered acidic and a higher rea...

Page 40: ...spa and refill it with clean water Add chlorine while jets are running and let them run for 1 2 hour Or disinfect the spa with large chlorine dosed in the range of 8 10 PPM Use a chlorine test kit or...

Page 41: ...inity Total alkalinity TA is the amount of carbonate bicarbonate and hydroxyl ions in the water TA total alkalinity affects and protects the PH of water Proper TA levels allow other chemicals to work...

Page 42: ...before running additional tests STEP 2 Adjust PH ideal range 7 4 7 6 Test water follow directions on manufacturer s label and add required amount of chemicals with jets on STEP 3 Adjust bromine chlori...

Page 43: ...every 3 4 weeks On initial start up filters should be cleaned every second day for the first two weeks of operation Always turn off the spa before removing and cleaning the filter cartridges To clean...

Page 44: ...remove water from the plumbing lines If you do not plan to use your spa during the winter winterize to eliminate any water trapped in the system 1 Prior to draining the spa ensure the power is turned...

Page 45: ...ective action OVERHEAT 1 Too much filtration 2 Temperature setting too high 1 Reduce the number of filter cycles and or the filter cycle duration 2 Turn down the thermostat Will not turn on in any mod...

Page 46: ...tall it for usage in summer and winter time DURING SUMMER TIME THE CURTAIN INSULATION MUST BE REMOVED FROM THE SKIRT Remarks Outside temperature for summer time is from 15 C and upwards Warning the cu...

Page 47: ...emarks Warning When using the curtain insulation during winter time it will save a lot on your energy cost But be aware of to remove it during summer time Failure in not remove it can seriously effect...

Page 48: ...Fill the spa with water then check each connection for all pumps and the spa pak and hand tighten them IMPORTANT Airlock RE LEASE ACTION Fill in your spa When you fill the water into spa please inser...

Page 49: ...to loose the downside plug on the circulation pump wet end loosen the plug and let some water flow out of the pump then tighten the plug again Prime mood Pr is displayed in control panel Check again f...

Page 50: ...Model2310 Ver 14 0 49 Safety Valve there is a safety valve behind the drainage valve when a failure in the drainage valve happens Can close the safety valve to stop the water to flow out to the floor...

Page 51: ...the malfunction this time you need to adjust the black valve in the drain valve as follows 1 Open the drain valve and take out the black valve and check for debrises 2 Use a clamp to hold the nut and...

Page 52: ...er 14 0 51 15 HOW TO REPLACE THE JETS PUMPS AND CIRCULATION PUMP 1 For jets pump a Just need to remove the two front side screws nuts the back side is installed the aluminium sheet to secure the base...

Page 53: ...Model2310 Ver 14 0 52 b After remove the front side fixing nut put up the front side to loosen the pump base from the bolt then can pull out the pump...

Page 54: ...Model2310 Ver 14 0 53 2 For the circulation pump a Remove the fixing nut on the bolt on the Right side the left side is installed the aluminium sheet to secure the base of the pump...

Page 55: ...Model2310 Ver 14 0 54 b After remove the right side fixing nut put up the right side to loosen the pump base from the bolt then can pull out the pump...

Reviews: