| Appendix
148
YLS-K
12.1.2 Messages of the Alarms tab.
Type and number of alarms
The type and number of the alarms varies depending
on the configuration of the laser.
Message
E-Stop
Type
Alarm
Reset
Automatic
Description
The alarm
E-Stop
is activated as soon as an internal or external
E-Stop
has been triggered. The
E-Stop
alarm usually appears in connection
with another alarm that represents the actual cause for the
E-stop
. The
indicator light (Interlock) on the front side of the laser lights up yellow
(
Possible
causes
Another alarm is output that is responsible for the
E-Stop
.
Fault diagnos-
tics / trou-
bleshooting
Correct the cause of the alarm / fault.
The alarm E-Stop will then be automatically reset.
Message
E-Stop button
Type
Alarm
Resetting
Automatic
Description
The alarm
E-Stop
button is activated when the
E-Stop
button on the
front side of the laser cabinet is pressed. Pressing the E-Stop button
opens the internal safety circuit. The alarm leads to a shutdown of the
laser power supply and therefore the laser emission. The indicator light
(Interlock) on the front side of the laser lights up yellow.
Possible
causes
E-Stop button
is pressed.
Analysis / trou-
bleshooting
ð
Unlock the E-Stop button by turning 45° clockwise.
The alarm E-Stop button will then be automatically reset.
Message
External E-Stop
Type
Alarm
Reset
Automatic