| Maintenance
124
YLS-K
Figure 76:
Removing the left cover
5.
Look through the membrane mount, and check whether the mem-
brane is present and undamaged.
The membrane is a replacement part and is delivered in an assembly to-
gether with the membrane mount and the membrane holder.
2
1
3
4
Figure 77:
Replacing the water drain
Item Designation
Item Designation
1
Membrane mount
3
Membrane holder
2
Water-soluble membrane
4
Drain nut