YLR-SERIES USER GUIDE
46
COMPUTER INTERFACE / COMMANDS | IPG PHOTONICS
C
C
O
O
D
D
E
E
D
D
E
E
S
S
C
C
R
R
I
I
P
P
T
T
I
I
O
O
N
N
E
E
X
X
A
A
M
M
P
P
L
L
E
E
S
S
ROP
Read Output Power
– Reads the output power in watts. The
response will be the command echoed back, a delimiter of “: “,
and then either the power in watts, “Off” if the emission is off,
or “Low” if the power is below the reliable measurement
threshold of the laser.
Sent:
“ROP”
Response:
“ROP: 96”
(Indicates that the output
power is 96 watts)
Sent:
“ROP”
Response:
“ROP: Off”
(Indicates that emission is off)
Sent:
“ROP”
Response:
“ROP: Low”
(Indicates that the output
power is below the accurate
measurement range of the
laser)
RPP
1
Read Peak Power
– Reads the output peak power in Watts.
The response will be the command echoed back, a delimiter,
and then the power in watts, “Off” if the emission is off, or
“Low” if the power is below the reliable measurement
threshold of the laser.
Sent:
“RPP”
Response:
“RPP: 730”
(Indicates that the output peak
power is 730 watts)
Sent:
“RPP”
Response:
“RPP: Off”
(Indicates that emission is off)
Sent:
“RPP”
Response:
“RPP: Low”
(Indicates that the output
power is below the accurate
measurement range of the
laser)
RPRR
4
2
Read Pulse Repetition Rate - Reads the pulse repetition rate.
The response is the command echoed back, followed by a
delimiter of “: “, and then the pulse width in Hz.
Sent:
“RPRR”
Response:
“RPRR: 10”
(Indicates that the PRR is 10
Hz)
RPW
Read Pulse Width - Reads the pulse width. The response is
the command echoed back, followed by a delimiter of “: “, and
then the pulse width in milliseconds (ms).
Sent:
“RPW”
Response:
“RPW: 5.5”
(Indicates that the pulse width
is 5.5 ms)
RSN
Read Serial Number
– Reads the serial number of the device. Sent:
“RSN”
Response:
“RSN: 6103081”
1
PULSE MODE ONLY
2
GATE MODE ONLY
Summary of Contents for YLR Series
Page 1: ...P21 010078 REV A 02 07 2012 DCO 524 YLR SERIES USER GUIDE...
Page 2: ......
Page 3: ......
Page 4: ......
Page 10: ......