RO Membrane Replacement
1.
Disconnect the black hose from the top cap of
the RO housing.
2.
Remove the clamp holding the top cap on.
3.
Remove the top cap by using a screwdriver to
pry the top cap up. There are two notches on
opposite side of each other to pry cap up. Be
careful not to damage.
4.
Remove RO membrane by using needle nose
plyers. Grab one of the spokes and pull up
.
5.
Apply Magic lube to the bottom nipple and top
seal of the RO membrane.
6.
Insert membrane into pressure vessel, nipple
goes down and the seal is at the top.
7.
Apply Magic lube to the o-rings on the cap and
install on pressure vessel.
8.
Install the clamp to hold cap on.
9.
Install black hose.