background image

Filter Installation

Carbon Sediment cartridge Installation

The 

5 micron carbon/sediment filter cartridge

 is

the first

 

filter the feed water goes through.

 

Install it in

the housing on

 

the right side, next

 

to the water

supply hose inlet fitting

.

1.

Slide the small filter housing wrench up from under

 

the bottom of the white housing and turn CCW to

 

loosen. Remove the tool and spin housing

 

completely off.

2.

Lubricate o-ring on housing with Magic Lube

o-

ring lubricant.

3.

Remove plastic wrapping on new filter cartridge.

 

Position center hole on shouldered ring on bottom

 

of housing.

4.

Screw housing into base and tighten with small

 

filter housing wrench.

 Do not overtighten.

DI resin cartridge Installation:

1.

Slide the 

small

 filter housing wrench up from under the bottom of the 

white

 housing and

turn

 

CCW

 

to loosen. Remove tool and spin housing completely off.

2.

Lubricate o-ring on housing with Magic Lube o-ring lubricant.

3.

Remove cartridge from the sealed bag and place into housing with seal washer in the

up position

 

and locate the bottom hole on shouldered ring inside the bottom of the

housing.

4.

Screw housing into base and tighten with filter housing wrench.

  Do not overtighten.

The 

DI filter cartridge

 is the final filter and removes the rest of the impurity's after the RO.

 Install it in the housing on the left side, next to the pure water discharge fitting.

p.

5

Summary of Contents for Ultra Pure Systems Hydro Cart Compact

Page 1: ...t Compact Reverse Osmosis Deionizing water production machines designed for water fed pole window cleaning OPERATIONS MANUAL 12450 Oliver Avenue South 300 Burnsville MN 55123 651 686 5399 Fax 651 686...

Page 2: ...O product water will be 4 ppm If your supply water is 700 ppm then the RO product water will be 14 ppm The RO product water then flows through the deionizing DI resin which removes the balance of the...

Page 3: ...ousing wrench Qty 1 50 ft hose for pure water to pole Qty 1 Magic Lube o ring lubricant Qty 1 TDS meter Qty 1 RO Protect Membrane Storage Qty 1 Waste water hose Qty 1 Axel Qty 2 Wheels Qty 2 Axel spac...

Page 4: ...and Filter Assembly 1 Place hand on frame align holes 2 Place washers on 2 1 2 long bolts 3 Insert bolts through holes 4 Attach nuts and washer on bolts 5 tighten with 1 2 wrench 6 Connect the long ho...

Page 5: ...ew housing into base and tighten with small filter housing wrench Do not overtighten DI resin cartridge Installation 1 Slide the small filter housing wrench up from under the bottom of the white housi...

Page 6: ...de of each other to pry cap up Be careful not to damage 4 Remove RO membrane by using needle nose plyers Grab one of the spokes and pull up 5 Apply Magic lube to the bottom nipple and top seal of the...

Page 7: ...le hose to the other end of the 50 foot hose 4 Connect waste water hose to an area that can accept the water such as shrubs trees grass or drainage that leads to a storm drain Attach an extra garden h...

Page 8: ...ctancy of the DI resin cartridge is based on the TDS level of the RO water going into it The RO will remove up to 98 of the TDS from the feed water Example The feed water supply from a garden hose at...

Page 9: ...e RV antifreeze propylene glycol may be used if freeze protection for system is required see fig B 2 Reinstall green hose to the inlet when the solution starts coming out 3 Slowly pour solution into t...

Page 10: ...ce sediment filter High wastewater flow with low pure water flow good system pressure 1 Remove DI cartridge and retest 2 Extremely cold water supply 3 Plugged RO membrane Replace RO membrane High pure...

Page 11: ...marks inside the bucket or a measuring cup container Flow testing procedure With water running from hose being tested direct flow into bucket for exactly 1 minute while timing with watch Measure volum...

Page 12: ...Supply water pressure _______________ psi 5 Place green waste water hose on the ground to allow water to flow onto the ground or into a drain For testing purposes do not connect a pole hose Wait for 1...

Page 13: ..._ ______ 4 gpm minimum Check with local water authority Varies by season and region 40 psi minimum Specifications ______ ______ ______ ______ ______ Identify the parameters that are outside of the nor...

Page 14: ...20 17 17 7 2 10 9 24 23 8 1 10 32 22 22 19 18 14 12 10 15 6 4 5 3 11 21 25 17 25 21 28 27 26 30 31 33 34 33 18 Exploded View p 14...

Page 15: ...2ft each NS BD515257 Clamp 2 21 BD505136 Pressure Vessel Asm 4040 Stainless Steel 1 22 BD555077 Clamp Band 10 L x 3 4 W SS 2 23 BD410513 Hex Bolt SS 1 4 28x 1 5 L 4 24 BD431000 Flat Washer USS 1 4 SS...

Page 16: ...p 16 Notes...

Page 17: ...ys and is found defective the owner will be credited for the cost of the replacement part including shipping and handling Wear items exempt from warranty include belts carbon brushes power cords wheel...

Page 18: ...ply or not apply based on your specific IPC Eagle unit If such defects occur this warranty is void if service is attempted by non authorized IPC Eagle service providers To register your product go onl...

Reviews: