Ultra Pure series
Hydro Cart Compact
long
term storage instructions
System Preparation:
1.
Remove sediment filter and carbon filter, empty water. Reinstall empty
housings.
2.
Set green waste water hose on ground to drain system empty. (
see fig. A
)
3.
Remove cap on top of RO pressure vessel.
4.
Remove DI resin cartridge. Reassemble empty DI pressure vessel.
5.
Allow DI resin cartridge to drain for an hour. Then wrap it securely in
plastic to prevent it from drying out. Store indoors to protect from freezing.
RO Protect Solution preparation and application:
1.
Pour entire package of RO Protect
™
into 1 gallon of pure water or distilled
water, mix thoroughly ensuring all powder has been dissolved.
Note: RV antifreeze (propylene glycol) may be used if freeze protection for
system is required. (
see fig. B
)
2.
Reinstall green hose to the inlet when the solution starts coming out.
3.
Slowly pour solution into the top of the RO pressure vessel(s). (
see fig. C
)
4.
Allow time for solution to settle into the membrane, top off as needed,
reinstall all covers and store.
RO Protect
™
RO Membrane Protection & Storage Solution
A
MSDS
- www.ipceagle.com/MSDS
Set green discharge hose onto the ground
and let waste water flow out of the sysem.
Pour entire package of
RO Protect™ into 1gallon
of pure water or distilled
water, mix thoroughly
ensuring all powder has
been dissolved.
Note: RV antifreeze
(propylene glycol) may be
used if freeze protection
for system is required.
Slowly pour solution into the top of the open
RO pressure vessel(s). Reinstall green hose to
the inlet when the solution starts coming out.
B
C