Troubleshooting Procedures
System performance evaluation:
In order to properly evaluate and troubleshoot the system, you will need to
perform a complete
set of tests on the unit. These tests will help identify the cause of the problem.
To run these tests, you will need the following items:
•
Watch or clock with a sweep second hand.
•
3 gallon bucket.
•
Volume measurement method. This could be volume graduation marks inside
the bucket or a measuring cup/container.
Flow testing procedure:
•
With water running from hose being tested, direct flow into bucket for exactly 1
minute while timing with watch.
•
Measure volume of water and record the gallons per minute flow rate.
•
If water volume is very low, perform a 2 - minute test and divide flow by 2.
•
If water volume is more than your bucket can hold in 1 minute, take a 30 second
flow test and multiply the result by 2.
•
Record the results in gpm (gallons per minute).
Use this procedure for all of the required flow tests as listed in the following
System Testing
section.
p.