4
Safety Instructions
Transportation
• Please transport the UPS system only in the original package for shock and impact
protection
Preparation
• Condensation may occur if the UPS system is moved directly from cold to warm
environment. The UPS system must be absolutely dry before being installed. Please allow at
least two hours for the UPS system to acclimate with the environment
• Do not install the UPS system near water or in moist environment
• Do not install the UPS system in direct sunlight exposure or near heating sources
• Do not block ventilation holes in the UPS housing
Installation
• Do not connect appliances or devices which would overload the UPS system (e.g. laser
printers) to the UPS output sockets
• Place cables safely in a way that no one can step on or trip over them
• Do not connect domestic appliances such as hair dryers to the UPS output sockets
• The UPS can be operated by any individuals with no previous experience
• Connect the UPS system only to an earthed shockproof outlet which must be easily
accessible and close to the UPS system
• Please use only VDE-tested, CE-marked (or UL-marked for 100/110/115/120/127 VAC
models) main cable (e.g. the main cable of your computer) to connect the UPS system to
the building wiring outlet (shockproof outlet)
• Please use only VDE-tested, CE-marked (or UL-marked for 100/110/115/120/127 VAC
models) power cables to connect the loads to the UPS system
• When installing the equipment, ensure that the sum of the leakage current of the UPS and
the connected devices does not exceed 3.5mA
• Temperature Rating – Units are considered acceptable for use in a maximum ambient of
40C (104F)
• For Pluggable Equipment – the socket-outlet shall be installed near the equipment and shall
be easily accessible
• Operating altitude from 0-3000 meter
Operation
• Do not disconnect the main cables on the UPS system or the building wiring outlet
(shockproof socket outlet) during operations since this would cancel the protective earthing
of the UPS system and of all connected loads
• The UPS system features its own, internal current source (batteries). The UPS output
sockets or output terminals block may be electrically live even if the UPS system is not
connected to the building wiring outlet
•
In order to fully disconnect the UPS system, first press the OFF/Enter button to disconnect
the main cables.
•
Prevent any fluids or other foreign objects from entering the inside of the UPS system