0024
A non-numeric value was entered in a numeric-only field.
• Press RESET and continue.
•
0026
The Field key was pressed to exit a numeric-only field,
but last position of the field is not numeric.
• Press RESET and correct the last position of the field.
•
0027
A key was pressed not used by the display module
• Press RESET and continue using valid keys.
• 0029
Second key pressed during the diacritic mark key function
was not a valid combination.
• Press RESET and enter a valid combination.
• 0040
The Data Set Ready line is inactive, and should be active.
• Recovery must be made at the remote control unit.
• 0042
The Receive Clock signal failed.
• Recovery must be made at the remote control unit.
•
0043
The Data Set Ready line is active and should be inactive.
• Recovery must be made at the remote control unit.
• 0044
The 30-second communications time-out expired without
valid data received.
• Recovery must be made at the remote control unit.
•
0045
Data Set Ready will not activate.
• Recovery must be made at the remote control unit.
•
0050
Either the Clear to Send line was inactive while the
Request to Send line was active or the Clear to Send line
was active while the Request to Send line was inactive.
• Recovery must be made at the remote control unit.
•
0051 The transmit clock signal failed during a transmit
operation.
• Recovery must be made at the remote control unit.