Operation Manual of INVT CHS100 AC Servo Drive 3 Installation
10
3.1 Environmental Requirement
3.1.1 Temperature
Environment temperature range: -10°C ~ +45°C.
3.1.2 Relative humidity
RH
≤
90%.
No condensation is allowed.
3.1.3 Altitude
The servo drive can run at the rated power if the installation site is less than
1000m(including 1000m) above the sea level. But it has to derate if the altitude
exceeds 1000m. See the following figure for details:
Figure 3.1 Relationship between output current and altitude.
3.1.4 Other environment requirements
The servo drive can not bear fierce impact or shock. So the oscillation range should be
less than 5.88m/s
2
(0.6g), 10Hz~60Hz.
The servo drive should keep away from the electromagnetic radiation source.
The servo drive should keep away from water and condensation.
The servo drive should keep away from contaminative air, such as corrosive gas, oil
mist and conductive dust.
The servo drive should keep away from direct sunlight, oil mist, steam and vibration
environment.