SY S T E M O V E R V I E W
SY S T E M O V E R V I E W
Ventilation system iV-Smart+ / sMove controller
•
Operating instructions
Ventilation system iV-Smart+ / sMove controller
•
Operating instructions
Function
The iV-Smart
+
ventilation system is used to provide ventilation for living rooms and bedrooms.
An integrated thermal accumulator in combination with the reversible fan Xenion and the
JXLGLQJYDQHVHQVXUHVRSWLPXPKHDWUHFRYHU\ZLWKPD[LPXPDLUÀRZVLQLWVFODVV
The ventilation unit operates on the principle of heat
recovery by changing the direction of the fan. The
integrated thermal accumulator charges itself with heat
HQHUJ\IURPWKHURRPVDLUDVLWÀRZVWRWKHH[WHULRU
(extract air). After 70 seconds, each Xenion reversible
fan changes direction. When the reversible fan
changes direction, it releases the stored heat energy
into the incoming outside air (supply air).
For this principle to work correctly and to ensure the
room’s pressure stability the incoming air and extract
air volumes must match, i. e. two iV-Smart
+
ventilation
units are required. These are operated in pairs in push-pull operation: One ventilation unit
works in supply air mode while the other works in extract air mode at the same time.
Due to the Xenion reversible fan's high pressure built-up and active speed control (integrated
ZLQGVWDELOLVHUWKHDLUÀRZZLWKLQWKHV\VWHPLVNHSWQHDUO\FRQVWDQW7KXVWKHDLUÀRZ¶V
sensitivity to pressure variation meets the requirements of class S3 according to EN 13141-8
PD[DLUÀRZGHYLDWLRQDW3D
In order to ensure the full functioning of the ventilation system throughout the entire year, an
DGGLWLRQDOÀH[LEOHWHPSHUDWXUHVHQVRULVLQWHJUDWHGLQWRWKH;HQLRQUHYHUVLEOHIDQ7KLVPHD
-
VXUHVWKHWHPSHUDWXUHRIWKHDLUÀRZ,IWKHWHPSHUDWXUHIDOOVEHORZ&WKHUHYHUVLEOHIDQ
is automatically switched to extract air mode for 4 cycles. This allows the thermal accumulator
to heat up again and prevents cooling of the interior due to cold drafts. During this phase, the
PRGHWKDWKDVEHHQVHWRQWKHFRQWUROOHULVLQHႇHFWLYH6XEVHTXHQWO\WKHFRQWUROOHUVZLWFKHVWKH
ventilation unit back to the originally selected mode.
$PXOWLXVHGXVW¿OWHURI¿OWHUFODVV*LVLQWHJUDWHGGLVFUHHWDQGHDV\RIDFFHVVLQWRWKHLQQHU
FRYHU,W¿OWHUVRႇUHOLDEO\GXVWVDVZHOODVDOOHUJHQLFSDUWLFOHVVXFKDVSROOHQIURPWKHDPELHQW
DLUEHIRUHLWFDQHQWHUOLYLQJVSDFHV'XVW¿OWHUVDUHVHDVRQLQGHSHQGHQW)RUVSHFLDOUHTXLUH
-
PHQWVPLFURSROOHQDQGDFWLYDWHGFDUERQ¿OWHUVDUHDYDLODEOHDVDQRSWLRQ
A decentralised ventilation system is based on the free movement of air between individual
pairs of ventilation units. Therefore, internal doors must not have air-tight seals.
Ensure adequate air transfer measures: An air gap of about 10 mm below the door, unscrew the
hinges by 5 mm, use a ventilation grille or similar (cross ventilation).
The ventilation unit is controlled via one of the inVENTer system controllers. Depending on the
controller, operating modes and functions may be selected.
70 s
Construction
Figure 1: Overview of iV-Smart
+
ventilation unit
Components
1 Protective hood base plate
2 Protective hood cover
Thermal accumulator insert
(thermal accumulator and inVENTron
®
)
Flair inner cover
Exterior closure:
Standard version:
Nova/Smart protective hood
Wall sleeve
S
rt
Nova
A
!
Reveal grille
2 Louvres
3 Flat duct sliding sleeve
4 Wall bracket (2 x)
5
&RUQHUÀDWGXFW
Corner version:
5HYHDOJULOOHDQGÀDWGXFW
O" #$
8
!
Metal sleeve with Neopor insert
2 Protective grille
Ohio version: Ohio protective hood
6 Wall sleeve R-D160
7 Recess for fan BUS (interior wall side)
8 Thermal accumulator with insulation
9 Thermal accumulator handle
10 Standard guiding vane (broad)
11 Xenion reversible fan
12 Slim guiding vane (slim)
13 Guiding vane knob
14 BUS plug connection
15 Inner cover base plate
16
'XVW¿OWHU
17 Inner cover panel
18 Spacer (4 x)
&RUQHUÀDWGXFWDQGUHYHDOJULOOH
A
B
D
C
A
B
C
D
1
5
7
8
10
11
13
16
6
15
2
2
1
2
1
2
3
4
9
12
14
17
18
1
Standard version
Ohio version
Corner version