Maintenance activity
Half-yearly
Thermal
accumulator
Remove the thermal accumulator and clean it
under running warm water.
Guiding vanes
Remove the guiding vanes from the fan.
Clean the guiding vanes using a soft brush or
under warm running water.
Reversible fan
Clean the fan blades with a brush.
Wall sleeve
Clean the wall sleeve with a damp cloth.
&DUERQ¿OWHU
5HSODFHWKHDFWLYDWHGFDUERQ¿OWHU
Sound protector
Replace the sound protector.
Sound absorbing insert
*HQWO\SDWRႇWKHVRXQGDEVRUELQJLQVHUW
Yearly
Wind protection insert
Wash the wind protection insert with warm water
and detergent.
Inner cover base plate
Clean the surface of the base plate with a damp
cloth.
Cleaning from the exterior
Yearly
Exterior closure:
weather protection hood
Clean the surface of the cover and the protective
grille with a damp cloth.
Flat duct
Remove the reveal grille. Clean the interior side of
WKHÀDWGXFWZLWKDGDPSFORWK
6FUHZWKHUHYHDOJULOOHWRWKHÀDWGXFW
5.1
Remove the inner cover panel
7RFOHDQDQGPDLQWDLQWKHYHQWLODWLRQXQLW¿UVWUHPRYHWKHSDQHORIWKHLQQHUFRYHU
5HTXLUHPHQWV7KHYHQWLODWLRQXQLWLVVZLWFKHGRႇ
Ö
You have removed the panel of the inner cover.
20
21
C L E A N I N G A N D M A I N T E N A N C E
C L E A N I N G A N D M A I N T E N A N C E
Ventilation system iV-Smart+ / sMove controller
•
Operating instructions
Ventilation system iV-Smart+ / sMove controller
•
Operating instructions
q
Cleaning and maintenance
r tJ
u
vwKV E
+
ventilation units and the sMove controller are virtually maintenance-free.
Any necessary cleaning or maintenance work can be carried out by the user by following these
instructions.
TIP:
Before performing cleaning or maintenance tasks, disconnect the controller's power supply
and put on gloves.
Detergents
NOTICE
The plastic/glass surface of the inner panel/controller is not scratch-resistant
and may be damaged.
• Do not use sand, soda, acid or chlorine-based cleaning agents.
A commercially available detergent in warm water can be used for cleaning. The following tools
may be used for cleaning:
• lint-free, soft cloth
• soft brush
• Vacuum cleaner
Recommended maintenance
The maintenance tasks and intervals listed here are recommended by inVENTer GmbH to
maintain the functionality and performance of the iV-Smart
+
ventilation system.
Depending on requirements and/or air quality, your personal maintenance plan may deviate
from these recommendations.
p
(
'
Assembly
Maintenance activity
Cleaning from the interior room
Monthly
0LFUR¿OWHU
5HSODFHWKHPLFUR¿OWHU
3ROOHQ¿OWHU
5HSODFHWKHSROOHQ¿OWHU
Inner cover
Clean the surface of the panel with a damp cloth.
sMove controller
Clean the acrylic glass cover and side surfaces
with a damp cloth.
Brush the ventilation slots free.
Quarterly
'XVW¿OWHU
:DVKWKHGXVW¿OWHUZLWKZDUPZDWHUDQG
detergent.
Or
5HSODFHGHIHFWLYHGXVW¿OWHUV
Ź
Open the inner cover (
3.1).
Ź
Press the side detent lugs inwards on the inner
cover base plate's spacers.
Ź
Pull the inner cover panel forwards.
Ensure that all t
he spacers disengage.
Ź
Remove the inner cover panel from the front.
CLICK