6
7
U S E R A N D S A F E T Y I N S T R U C T I O N S
SY S T E M O V E R V I E W
Ventilation system iV-Smart+ / sMove controller
•
Operating instructions
Ventilation system iV-Smart+ / sMove controller
•
Operating instructions
2
System overview
The iV-Smart
+
ventilation system is designed to ventilate living rooms and bedrooms in single-
and multi-family houses, hotels and guest houses, rooms in public facilities and work rooms in
RႈFHEXLOGLQJV,WLVXVXDOO\ORFDWHGLQWKHH[WHULRUZDOO
The construction of the iV-Smart
+
product range complies with the applicable European direc-
tives.
The ventilation unit iV-Smart
+
comprises a wall sleeve into which a thermal accumulator insert
is installed, as well as an inner cover and an exterior closure.
The thermal accumulator insert contains the ceramic thermal accumulator and inVENTron
®
. The
ÀRZRSWLPLVHGGHVLJQRI
inVENTron
®
, the two guiding vanes with embedded reversible fan Xenion
®
HQVXUHVHႈFLHQW
FDSDFLW\XWLOLVDWLRQDQGHYHQÀRZWKURXJKWKHWKHUPDODFFXPXODWRU
It is controlled via one of the following inVENTer
®
system controllers
1)
:
• sMove s4 • sMove s8 • MZ-Home
Components
VHH¿JSDJH
•
,QQHUFRYHULQFOGXVW¿OWHURIFODVV*
• Thermal accumulator insert
(thermal accumulator and inVENTron
®
)
• Wall sleeve
• Exterior closure
•
3ROOHQPLFURDQGDFWLYDWHGFDUERQ¿OWHU
options available
• Sound and wind protection options
available as accessory
Models
• Standard version:
iV-Smart
+
ventilation units with driving rain proof weather protection hood
Nova or Smart (white/grey/Nord/custom colour)
• Corner version:
iV-Smart
+
YHQWLODWLRQXQLWVZLWKÀDWGXFWLQWHJUDWHGLQWRWKHWKHUPDOLQVXODWLRQ
layer and reveal grille (white/grey/Nord/custom colour).
Due to the reveal grille in the window reveal the ventilation unit disappears subtly into the
external wall.
• Ohio version:
iV-Smart
+
ventilation units with weather protection hood Ohio (grey)
It is designed as an solution for buildings with the special requirements of particularly thin
H[WHULRUZDOOVHJLIGXHWRFRQVWUXFWLRQUHTXLUHPHQWVQRWKHUPDOLQVXODWLRQPD\EH¿WWHG
•
1HYHUXVHWKHXQLWZLWKRXWWKH¿OWHUVDQGLQQHUFRYHU
• Use the sMove controllers exclusively to control inVENTer ventilation devices with heat
recovery.
If your device has a defect, contact your nearest distributor or our technical service.
Any kind of use other than the intended use will exclude all liability claims.
Improper use
Any use that is not mentioned in the intended use section, is considered to be improper.
Do not install the equipment in areas which...
• Contain (or may contain) strong oils or lubricants.
•
&RQWDLQRUPD\FRQWDLQÀDPPDEOHJDVHVOLTXLGVRUYDSRXUV
• Contain (or may contain) extreme dusts.
• Are exposed to ambient temperatures below -20 °C and above 50 °C.
• Contains obstacles that hinder access to, or removal of, the unit’s components.
• it is used to dry up the structure.
4XDOL¿HGSHUVRQQHO
The equipment/system may only be operated and maintained in conjunction with this documen-
tation and the documentation for the controllers.
Any necessary cleaning or maintenance tasks can be carried out by the user by following the
instructions. Operation and/or maintenance of the ventilation unit and controller must not be
carried out by children and/or persons who are not fully capable of doing so due to their
physical, sensory or mental capabilities, inexperience or lack of knowledge.
Conformity
The ventilation unit complies with the applicable technical safety requirements and standards
for household and similar electrical appliances. They are conform to the following European
directives:
• 2014/30/EC: Electromagnetic compatibility directive
• 2009/125/EC: Energy related products directive
• 2014/35/EC: Low voltage directive
• 2011/65/EC: Restriction of certain Hazardous Substances (RoHS) directive