28
29
T R O U B L E S H O O T I N G A N D D I S P O S A L
S P E C I F I C AT I O N S
Ventilation system iV-Smart+ / sMove controller
•
Operating instructions
Ventilation system iV-Smart+ / sMove controller
•
Operating instructions
M
'
,
Possible cause
Remedy
Wrong controller
function when
interface is
connected
Upper jumper is incorrectly/
not connected
Check position of the jumper on the back
of the operating unit:
Attached: Operating mode OFF
Not attached: Ventilation mode
Controller does
not function.
Operating unit is incorrectly/
not connected.
Check wiring.
No electrical contact.
Check cables. Ensure cables are stripped
VXႈFLHQWO\DSSUR[PP
Indicator lights
do not light up.
Faulty controller.
Replace controller.
There is no power.
Check power supply.
Slide control
defective.
Replace controller.
Disassembly
Disassemble the ventilation unit in the opposite sequence to the assembly sequence. You can
subsequently dispose of your old device. Please note the disposal recommendation outlined
below.
Disposal
The products described in these installation and operating instructions contain valuable
materials which can be recovered and recycled. Further information about the used
materials are provided in the corresponding installation instructions.
7KHVHSDUDWLRQRIZDVWHPDWHULDOVLQWRGLႇHUHQWYDULHWLHVIDFLOLWDWHVUHFRYHU\RIWKH
recyclable materials. Contact an electronic appliance disposal company to arrange
environmentally friendly recycling and disposal of your old system.
They will dispose of the product in compliance with the applicable national regulations.
6SHFL¿FDWLRQV
F
,
Value
iV-Smart
+
ventilation unit
Operating range [°C]
-20 – 50
$LUÀRZLQUHYHUVHRSHUDWLRQSXVKSXOOSHUXQLW
[m³/h]
8.5 – 29
([WUDFWDLUÀRZSHUXQLW>PñK@(1
17 – 58
Sound pressure level [dB (A)]
16 – 36
6WDQGDUGVRXQGOHYHOGLႇHUHQFH>G%@
Standard:
38 – 49
Corner:
39 – 47
Ohio:
34
+HDWUHFRYHU\>Ș
w
]
0.87
DLG E
I
A EK J
u
C
6 – 16
Power consumption [W]
1 – 3
Protection class (EN 61140) /
Type of protection (EN 60529)
III / IP20
)LOWHUFODVVVWDQGDUG¿OWHU(1
G4
$LUÀRZVHQVLWLYLW\DW3D(1
Class S3
Frost protection
Automatically due to push-pull operation
(up to -20 °C)
(QHUJ\HႈFLHQF\FODVV
local demand control
manual control
Conformity
sMove controller
Protection class (EN 61140) /
Type of protection (EN 60529)
II / IP20
Input voltage Switching PSU [V AC] [Hz]
230 / 50
Output voltage Switching PSU [V DC] [Hz]
24
Maximum power consumption s4/s8 [W]
11 / 20
Power consumption (Standby) [W]
< 1
Output voltage fan BUS [V DC]
6.7 – 15.3; 3 pole
Analogue input (optional) [V DC]
0 – 10, Control voltage
External switching contact (optional)
Potential free closer contact (NO)
Operating temperature [°C]
5 – 50
Conformity
A+
A