![Invacare 3LX Service Manual Download Page 57](http://html1.mh-extra.com/html/invacare/3lx/3lx_service-manual_2082378057.webp)
57
PROCEDURE 16
4-WAY VALVE
4
-
W
A
Y
V
A
L
V
E
PROCEDURE 16 (continued) - REPLACING 4-WAY VALVE/MANIFOLD ASSEMBLY/PILOT
VALVES
15. Repeat the STEPS 1 through 14 for other pilot valve.
16. Reinstall control panel (Refer to PROCEDURE 9 - REMOVING CONTROL PANEL).
CAUTION
Ensure that hoses behind control panel DO NOT contact cooling fan after control panel reinstal-
lation.
17. Plug power cord in and turn concentrator on to ensure proper operation.
18. Reinstall cabinet. (Refer to PROCEDURE 1 - REMOVING CABINET).
19. If any difficulties are encountered in this installation, contact Invacare Technical Service at
(800) 832-4707 or in Florida 1 - (407) 321-5630.
CAUTION
DO NOT overtighten locknut when installing it onto pilot valve stem. Damage to the plastic
manifold may occur.
Slotted Poppet
10. Use the flat blade screwdriver and tighten pilot valve stem clockwise until snug. (Reference: Torque
to 25-inch lbs. + 5-inch lbs.).
11. Install NEW label onto pilot valve coil yoke.
12. Position pilot valve coil with yoke at an approximate 60
O
angle to the left (as viewed from the front of
valve) to ensure spade connectors are not pulled or tensioned after reinstallation.
13. Use the flat blade screwdriver and hold the pilot valve stem in place.
14. Tighten locknut clockwise with the 9/16-inch wrench until snug to secure the stem and coil with yoke.
DO NOT OVERTIGHTEN. (Reference: Torque to 20-inch lbs. + 3-inch lbs.).
Manifold
Locknut
Spade Connectors
(Leave Wire
Connectors
Intact).
LEAVE
TOGETHER
Pilot Valve Stem
"O" Ring
Tapered End
Locknut
Pilot Valve
Stem
60
O
Pilot Valve
FIGURE 4 - REMOVING/INSTALLING PILOT VALVE POPPETS AND "O" RINGS
Yoke
New
Label
Coil
M a n i f o l d
Opening
Pilot Valve Coil
Yoke
Sieve Bed Hoses
Valve Body
(Reference)
New Label
Valve Body
(Reference)