NOTE
The Distribution Panel includes a 30 amp Ships Power Circuit Breaker as a provision for an
optional Generator installation. Between the 30 amp Shore Power and 30 amp Ships Power
Circuit Breaker is mechanical interlock. This interlock ensures that only one power source is
supplying the Distribution Panel at a time. To energize the panel from two sources would create
serious safety hazards.
To turn ON the Shore Power Circuit Breaker the interlock must be moved UP so that the circuit
breaker handle can be moved to the ON position. This interlock position will also ensure that the
Ships Power Circuit Breaker can not be turned ON.
AC DISTRIBUTION PANEL
NOTE
To protect your Shore Cord, Shore Cord Receptacle and AC equipment from undue damage from
arcing and current surges it is recommended that the following procedures be used for
connecting or disconnecting Shore Power to or from the AC Electrical System.
Connecting the Boat to Shore Power
AC OUTLET
AC OUTLET
MICROWAVE
REFRIG
AIR
CHARGER
SHIPS
POWER
SHORE
POWER
REVERSE
POLARITY
COND
SPARE
SPARE
AC VOLTS
0
50
100
150
1. Turn OFF all AC Accessories at the control (Air Conditioning for example) or turning
the accessory circuit breaker OFF (Refrigerator for example).
2. Turn OFF the 30 amp Shore Power Circuit Breaker
3. Connect the Shore Cord to the boat’s Shore Cord Receptacle
4. Connect the Shore Cord to the shore power source
5. Turn ON the 30 amp Shore Power Circuit Breaker
6. Turn ON AC Accessories at the control or turning the accessory circuit breaker ON.
H-4