2. FRESH
WATER
TANKS
here are two 20-gallon Fresh Water Tanks located under the Aft Splash-well.
he Fresh Water Tank Deck Fill Plate is located on the transom coaming on the Starboard side of
ck Fill Plate provides the means to fill the Water Tank from the cockpit.
o maintain the integrity of the Fresh Water system, do not fill the tanks with anything but fresh
fill Plate cap is always in place and tight.
n the Starboard hull side under the Deck fill plate. It
rovides the ability for the tanks to vent to the atmosphere for filling the tanks and relieving the
caused by the Fresh Water Pump.
OTE
re that the internal screen is free of debris.
es to purge the Fresh Water System of air. This will occur on the initial
filling o
ined or allowed to run dry. The purging
procedu
s
ter Pump ON at the Helm Switch Panel
4. Open each faucet slightly until a steady stream of water occurs.
faucets
rior to winter lay-up of the boat where below freezing temperatures can occur, drain and
em and sink drains.
he Forward Fish Box drainage system incorporates both a gravity drain and a macerating pump
he Macerator Pump is powered by the Port Battery System and a 20-amp circuit breaker
y placing the Macerator Pump switch handle to the ON position (UP) power is provided to the
tor Pump.
allows the switch
return to the OFF position. The noise of the pump will change distinctly once it begins to run
T
3. DECK FILL PLATE
T
the boat. The cap to the Deck Fill Plate is Blue and marked WATER.
The De
NOTE
T
water. Also, ensure the Deck
4. TANK
VENT
FITTING
The Fresh Water Tank fitting is located o
p
suction
N
Inspect the Tank Vent fitting periodically to ensu
5. PURGING THE FRESH WATER SYSTEM
It will be necessary at tim
f the system or after the tanks have been dra
re i as follows:
1. Fill the tanks to capacity with Fresh Water
2. Close all Faucets
3. Turn the Fresh Wa
5. Close all
6. WINTERIZATION
P
winterize the Fresh Water Syst
5. MACERATOR PUMP
T
for discharging the fluid and solid contents of the Fish Box.
The macerator is an impeller pump that grinds solids to a size suitable for discharging overboard.
T
protects its circuitry.
B
Macera
NOTE
Impeller pumps will destroy its impeller if allowed to run dry for a relatively short period of time. It
is for this reason that the Macerator Pump switch has a momentary action. To activate the pump
the switch handle must be held to the ON position. Releasing the switch handle
to
dry. Once this change is noticed, allow the switch to return to the OFF position.
D-8