Operation
The hand wash and dry cycle is activated when your hands are placed centrally into the wash bowl below the dispensing
nozzles. An infra-red sensor initiates the cycle when it detects hands in the bowl area. When the cycle starts, a sequence of
soap, warm water and hand dryer air are dispensed. Note that the hand dryer is programmed to cease operation shortly
after hands have been removed from the wash bowl, or when the pre-set dryer cycle time has been reached.
7.1.1
Soap Operation
There are 2 settings for soap delivery, LIQUID (default) or FOAM. The controls to set the required soap option are located
on engine unit. To change the settings the unit must be powered up. There are 2 controls that need to be altered:
1.
At the window to the left of the mains connector there is a small push button labelled ‘Soap’. Press and hold this
button to select the desired setting this will be confirmed by an illuminated LED.
2.
Adjust the soap selection switch to position 1.
Ensure that both button setting and soap selection knob position select the same operation. Failure to do so
may result in an incorrect operation.
Low soap level indicator:
A function on the unit can be enabled, to indicate that the soap container level is low. When this function is set to ON
(Default setting is OFF) and the soap is at a low level the bowl light will pulse once per second. To turn ON this
function refer to section 7.2 for “Advanced Adjustments” and select menu item F146 which is the setting for number
of soap operations before the warning light is activated. Setting this to 20 will activate the warning light after 2000
operations. The setting may require adjustment if the number of operations per full soap container is found to be
fewer or greater than the setting.
To reset the warning light there are two options.
a.
Press buttons 2 & 3 on the display together & hold for 5 seconds.