Thrii
Installation
Page
12
of
23
All information including dimensions, changes in design and material are subject
to manufacturer’s change without formal notice and without obligation. Intersan
assumes no responsibility for use of superseded or voided information. Verify all
rough-in information before installation. It is the responsibility of the installer to
conform with local and national codes.
Intersan Manufacturing Company
1748 West Fillmore St., Phoenix, AZ 85007
Phone: 800-999-3101 Fax: 602-254-1776
intersanUS.com
THRII-inst-Rev1
by
4.
Insert the 4 No. M10 x 150mm (6”) threaded rods through the corner angles on the support frame and into the
brackets as shown in figure above.
5.
Tighten all four (4) brackets until the wall frame is held securely in place in the wall opening. It is important that
the frame side members are not distorted when tightening to the wall, as this may prevent the hinge and catch
mechanisms from working properly.
6.
Once the frame is securely attached to the wall, if necessary make good any excessive gaps between the frame
and the wall that may not be covered by the fascia.
7.
Install the waste connector to the frame as shown in figure below along with the pipe adapter which then is
terminated to the deep seal waste trap as detailed in section 6.2 site preparation.
8.
Provide a cold water supply pipe to connect to the inlet connector on the support frame
.
Note that the water
inlet connector is ½” copper fitting on the main water supply.
If pipe sealing compound is used, avoid applying excessive amounts as particles of sealant can block water
filters and impede valve operation.
Before carrying out the following steps, flush the main water supply pipes to remove any debris and trapped
air. Failure to do so may result in damage and failure of the unit.
9.
Connect the deep seal waste trap to the outlet fitting on the support frame.
10.
Connect the supplied electrical cable to a 20 amp circuit equipped with an accessible circuit breaker and GFC� if
required per locally applicable code requirements.
6.4
Mounting the fascia
Ensure that the fascia is fully supported until both hinges are fully engaged. Failure to do so may damage the
hinges
For ease of installation it is recommended to have at least two people carry out this operation
Ø1-1/4”