46 von 54
Version 2.0 (04/2019) Online
Translation of the original operating manual
Troubleshooting
8
Troubleshooting
8.1
Troubleshooting
Symptom
Possible Cause
Help
ZoneControl is not working or is
working incorrectly
No power supply
¾
Check whether the output
voltage of the power supply
is within the specified voltage
range.
¾
Check the connections and
correct if necessary.
Wrong position of the DIP switches
¾
Check and if necessary
correct the position of the DIP
switches (see „DIP switches”,
page 21).
ZoneControl faulty or damaged
Internal fuse triggered or faulty
¾
Replace the ZoneControl.
RollerDrive is not working
RollerDrive is faulty or no power supply
¾
Check whether the output
voltage of the power supply
is within the specified voltage
range.
¾
Check the connections and
correct if necessary.
The ERROR signal is automatically
reset after elimination of the fault
and the ZoneControl immediately
performs a local reinitialisation of
the affected zone.
Conveyor process interrupted
Packages jammed
¾
Remove jammed packages.
The ERROR signal is automatically
reset after elimination of the fault
and the ZoneControl immediately
performs a local reinitialisation of
the affected zone.