22 von 54
Version 2.0 (04/2019) Online
Translation of the original operating manual
Product information
3.8
Meaning of signals
ZONE_STATUS
The ZONE_STATUS signal is the output signal of the handshake function of the ZoneControl. The assigned signal input
is ZONE_START.
The ZONE_STATUS signal is active when:
• The ZONE_START signal is active.
• The start or zone sensor is occupied (by regular in-feed of a package or by placing a package on a previously
empty zone).
The ZONE_STATUS signal gets in-active when:
• A package initially standing is conveyed into the following zone. When the zone sensor becomes free, the ZONE_
STATUS gets in-active providing no further package is following.
• If a package does not reach the zone sensor, the system assumes after 5 seconds that the package has been
manually removed and the ZONE_STATUS signal gets in-active.
• If a standing package is removed manually (and the zone sensor gets thereby freed), the RollerDrive continues
rotating for 2 seconds. If the sensor is not occupied again during this time and no other package follows, the
ZONE_STATUS signal gets in-active.
3.9
Dimensions